11.07.2015 Views

SYNTEC CNC Application manual - Winter Holztechnik

SYNTEC CNC Application manual - Winter Holztechnik

SYNTEC CNC Application manual - Winter Holztechnik

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Mechanical logic control alarm,MLC001 R40.0 X axle over positive hardware route limit002 R40.1 X axle over negative hardware route limit003 R40.2 X axle not back to the origin004 R40.3 X axle servo driver alarm009 R40.8 Y axle over positive hardware route limit010 R40.9 Y axle over negative hardware route limit011 R40.10 Y axle not back to the origin012 R40.11 Y axle servo driver alarm017 R41.0 Z axle over positive hardware route limit018 R41.1 Z axle over negative hardware route limit019 R41.2 Z axle not back to the origin020 R41.3 Z axle servo driver alarm025 R41.8 A axle over positive hardware route limit026 R41.9 A axle over negative hardware route limit027 R41.10 A axle not back to the origin028 R41.11 A axle servo driver alarm033 R42.0 B axle over positive hardware route limit034 R42.1 B axle over negative hardware route limit035 R42.2 B axle not back to the origin036 R42.3 B axle servo driver alarm041 R42.8 C axle over positive hardware route limit042 R42.9 C axle over negative hardware route limit043 R42.10 C axle not back to the origin044 R42.11 C axle servo driver alarm049 R43.0 Spindle servo driver alarm050 R43.1 Process liquid motor over load051 R43.2 Oil pressure system alarm052 R43.3 Air pressure not enough053 R43.4 Lubricant not enough054 R43.5 Process liquid not enough055 R43.6 Gripper is not closed056 R43.7 Tool system alarm<strong>SYNTEC</strong> <strong>CNC</strong> application <strong>manual</strong>ALARM message and HELP manufacture method :Show user default mechanical logic control alarm message (ALARM MESSAGE):Time : when ladder or macro send the alarm ,can send the related message of this alarm at thesame time , let operator to understand reason of alarmHow to :correct \<strong>CNC</strong>\APP file appchi.str(Chinese version),appeng.str(English version) ,the form below:indentify code = “1;MSG= alarm contents description”among,indentify code = 20000 add alarm code。example:want to show NO.65 contents of alarm is air pressue not enough,the form below:20065 = "1;MSG= air pressure not enough"alram NO.1 to NO.64(R40~R43) is system reserve,user can not definit in this area,or80

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!