<strong>SYNTEC</strong> <strong>CNC</strong> application <strong>manual</strong>48..51 each axle index counter : when index comes ,hardwrare copy value of absoluteposition recoder to index counter,this value can be lost pulse check ,intheory , accumulation of index counter ,should be equal to the distance ofmachine’s movement when motor start rotate ,this value will clear to 0 whenthe first time finding HOME56..60 each axle limit shift value : recorde the distance from limit switch to INDEXwhen finding HOME, ideal value is between motor 1/4 – 3/4 revolve ,or setthe value in 1/2 revovle79 software version number : controllers that <strong>SYNTEC</strong> build all have software versionnumber ,when you write the problem list ,please recorder this number at thesame time88