Non-Fatal Error Codes<br />

Error Message Err # Possible Cause<br />

Capture process not done 94 The requested comm<strong>and</strong> can’t be processed due to pos<br />

capture not being complete<br />

Capture process not active 95 The requested comm<strong>and</strong> can’t be processed due to pos<br />

capture not being active<br />

Capture process not enabled 96 Position capture cannot be executed<br />

ENCSTART while ACONFIG 97<br />

SERCOS test failure 999<br />

NO MESSAGE FAULTS<br />

SUPPORT<br />

Steady<br />

No Message Faults<br />

Non-<br />

Display Flashing State Fatal Fatal<br />

Fault Description<br />

≡ � � Watchdog (DSP)<br />

≡ � � Watchdog (HPC)<br />

-1 � � No Compensation<br />

-2 � � Invalid Velocity Control<br />

-3 � � Encoder not Initialized on attempt to enable<br />

-4 � � Encoder Initialization failure<br />

-5 � � AutoConfig failure<br />

L 1 � � Hardware CW limit switch open<br />

L 2 � � Hardware CCW limit switch open<br />

L 3 � � Hardware CW <strong>and</strong> CCW limit switches<br />

open<br />

L 4 � � Software CW limit switch is tripped<br />

(PFB>PMAX & PLIM=2)<br />

L 5 � � Software CCW limit switch is tripped<br />

(PFB