HOMETYPE<br />

Defines the type of homing function performed. This variable takes on a different meaning depending on the<br />

type of positioning selected (using PCMDMODE). In the following descriptions, “Home switch” refers to a<br />

digital input (IN1-IN3) that has been configured as a home switch by setting INxMODE = 10. “Marker” refers<br />

to an encoder’s index pulse or a resolver zero point:<br />

In Serial Position Mode<br />

(PCMDMODE = 0; also see MH; PFB is normalized to zero after the home search):<br />

0 homing with home switch <strong>and</strong> marker (PFB = 0).<br />

1 homing with home switch only (PFB = 0).<br />

2 homing with marker only (PFB = 0).<br />

3 present position is home on the rising edge of IN1, IN2, or IN3 with the corresponding<br />

INxMODE value set to 12 (PFB = 0).<br />

4 homing on marker with every drive enable, MH comm<strong>and</strong>, or on the rising edge of IN1-IN3<br />

with the corresponding INxMODE set equal to 12 (PFB = 0).<br />

5 homing on marker with every MH comm<strong>and</strong>, or on the rising edge of IN1-IN3 with the<br />

corresponding INxMODE set equal to 12 (PFB = 0).<br />

6 homing with home switch <strong>and</strong> marker (PFB = 0) on every MH comm<strong>and</strong> (firmware versions<br />

3.3.0 <strong>and</strong> later).<br />

7 homing with home switch only (PFB = 0) on every MH comm<strong>and</strong> (firmware versions 3.3.0 <strong>and</strong><br />

later).<br />

For HOMETYPE 0 to 3, the first execution of the homing comm<strong>and</strong> initiates a search for<br />

absolute machine zero. Executing successive homing comm<strong>and</strong>s causes an absolute move to<br />

zero position without searching for machine zero. For HOMETYPE 4 to 7, the drive searches<br />

for absolute machine zero on every home comm<strong>and</strong>, whether absolute machine zero has<br />

previously been detected or not.<br />

In Analog Position Mode<br />

(PCMDMODE = 1):<br />

HOMETYPES 0 to 7: same as for Serial Position Mode. When homing is complete, PFB is<br />

normalized (set equal to 0) at the current value of the analog input (ANIN). Example: when homing is<br />

complete, if 2 volts are present at the analog input, then PFB will be set equal to 0 at 2 volts of input.<br />

HOMETYPES 50 to 57: same as 0-7, except that when homing is complete, PFB is NOT normalized<br />

at the current value of ANIN. Instead, PFB is normalized at 0 volts input. * Caution! If there is a<br />

voltage on the analog input other than 0v <strong>and</strong> the drive is enabled, the motor will see this as a “comm<strong>and</strong><br />

to move” <strong>and</strong> move to the position specified by the analog input voltage.<br />

Firmware revision information: prior to firmware version 3.3.0, only Analog Position Mode HOMETYPES 0<br />

<strong>and</strong> 3 were available.<br />

Firmware Versions: 3.1.0 <strong>and</strong> later Type: switch mode (R/W) Units: N/A<br />

Range: 0 to 7<br />

(analog <strong>and</strong> serial position modes)<br />

Default: 0<br />

EEPROM: Yes<br />

50-57<br />

(analog position mode only)<br />

Drive Status: EN/DIS Opmodes: 8<br />

43