Setup and Reference Guide - Kollmorgen
Setup and Reference Guide - Kollmorgen
Setup and Reference Guide - Kollmorgen
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
HOMETYPE<br />
Defines the type of homing function performed. This variable takes on a different meaning depending on the<br />
type of positioning selected (using PCMDMODE). In the following descriptions, “Home switch” refers to a<br />
digital input (IN1-IN3) that has been configured as a home switch by setting INxMODE = 10. “Marker” refers<br />
to an encoder’s index pulse or a resolver zero point:<br />
In Serial Position Mode<br />
(PCMDMODE = 0; also see MH; PFB is normalized to zero after the home search):<br />
0 homing with home switch <strong>and</strong> marker (PFB = 0).<br />
1 homing with home switch only (PFB = 0).<br />
2 homing with marker only (PFB = 0).<br />
3 present position is home on the rising edge of IN1, IN2, or IN3 with the corresponding<br />
INxMODE value set to 12 (PFB = 0).<br />
4 homing on marker with every drive enable, MH comm<strong>and</strong>, or on the rising edge of IN1-IN3<br />
with the corresponding INxMODE set equal to 12 (PFB = 0).<br />
5 homing on marker with every MH comm<strong>and</strong>, or on the rising edge of IN1-IN3 with the<br />
corresponding INxMODE set equal to 12 (PFB = 0).<br />
6 homing with home switch <strong>and</strong> marker (PFB = 0) on every MH comm<strong>and</strong> (firmware versions<br />
3.3.0 <strong>and</strong> later).<br />
7 homing with home switch only (PFB = 0) on every MH comm<strong>and</strong> (firmware versions 3.3.0 <strong>and</strong><br />
later).<br />
For HOMETYPE 0 to 3, the first execution of the homing comm<strong>and</strong> initiates a search for<br />
absolute machine zero. Executing successive homing comm<strong>and</strong>s causes an absolute move to<br />
zero position without searching for machine zero. For HOMETYPE 4 to 7, the drive searches<br />
for absolute machine zero on every home comm<strong>and</strong>, whether absolute machine zero has<br />
previously been detected or not.<br />
In Analog Position Mode<br />
(PCMDMODE = 1):<br />
HOMETYPES 0 to 7: same as for Serial Position Mode. When homing is complete, PFB is<br />
normalized (set equal to 0) at the current value of the analog input (ANIN). Example: when homing is<br />
complete, if 2 volts are present at the analog input, then PFB will be set equal to 0 at 2 volts of input.<br />
HOMETYPES 50 to 57: same as 0-7, except that when homing is complete, PFB is NOT normalized<br />
at the current value of ANIN. Instead, PFB is normalized at 0 volts input. * Caution! If there is a<br />
voltage on the analog input other than 0v <strong>and</strong> the drive is enabled, the motor will see this as a “comm<strong>and</strong><br />
to move” <strong>and</strong> move to the position specified by the analog input voltage.<br />
Firmware revision information: prior to firmware version 3.3.0, only Analog Position Mode HOMETYPES 0<br />
<strong>and</strong> 3 were available.<br />
Firmware Versions: 3.1.0 <strong>and</strong> later Type: switch mode (R/W) Units: N/A<br />
Range: 0 to 7<br />
(analog <strong>and</strong> serial position modes)<br />
Default: 0<br />
EEPROM: Yes<br />
50-57<br />
(analog position mode only)<br />
Drive Status: EN/DIS Opmodes: 8<br />
43