DISTIME<br />
Sets the amount of time to wait after motor speed goes below DISSPEED before the drive is disabled in the<br />
Active Disable process. Once motor speed goes below DISSPEED, the drive waits for the time period specified<br />
by DISTIME, <strong>and</strong> then disables the drive. See also ACTFAULT, DECSTOP, DISSPEED, <strong>and</strong> O1MODE=5.<br />
Firmware Versions: 2.1.0 <strong>and</strong> later Type: variable (R/W) Units: millisecond * 0.1<br />
Range: 0 to 65535 Default: 100 EEPROM: Yes<br />
Opmodes: All Drive Status: EN/DIS<br />
DIVISIONS<br />
Sets the number of divisions used for indexing (divides PROTARY).<br />
Only used when MODMODE = 1<br />
Firmware Versions: 3.7.0 <strong>and</strong> later<br />
Default: 4<br />
Range: 2 to 32767<br />
-2 to -32767<br />
31<br />
EEPROM: Yes<br />
DRIVEOK<br />
Displays the status of the drive faults.<br />
0 = faults exist<br />
1 = no faults exist<br />
Firmware Versions: All Type: switch (R/W) Units: N/A<br />
Range: 0, 1 Default: N/A EEPROM: No<br />
Opmodes: All Drive Status: EN/DIS<br />
DUMP<br />
Transmits all variables <strong>and</strong> their settings to the serial port terminal. This comm<strong>and</strong> actually outputs the<br />
EEPROM contents of the drive to the serial port, where the variables can then be reviewed or saved to a variable<br />
file (*.SSV).<br />
Firmware Versions: All Comm<strong>and</strong> Syntax: DUMP<br />
Opmodes: All Drive Status: EN/DIS<br />
DUALFB<br />
Enables/disables the reading of an external feedback signal through the C8 connector.<br />
0 = no dual loop<br />
1 = dual loop without checking for external feedback fault<br />
2 = dual loop with checking for external feedback fault<br />
The fault options above can relate to a line break; however, the motor must be in<br />
motion for this detection to occur. It can also indicate a wrong XENDIR<br />
parameter.<br />
Firmware Versions: 3.3 <strong>and</strong> later Type: switch (R/W) Units: N/A<br />
Range: 0, 1, 2 Default: 0 EEPROM: Yes<br />
Opmodes: 8 Drive Status: DIS