MSG<br />
Enables <strong>and</strong> disables the sending of error messages from the drive to the serial port.<br />
0 = disable messages<br />
1 = enable messages<br />
MSG = 1 is needed for proper operation of MOTIONLINK.<br />
Firmware Versions: All Type: switch (R/W) Units: N/A<br />
Range: 0, 1 Default: 1 EEPROM: Yes<br />
Opmodes: All Drive Status: EN/DIS<br />
MSININT<br />
MSININT is used with the sine encoder option <strong>and</strong> sets the interpolation level of the drive.<br />
Firmware Versions: 3.2.0<br />
(3.3.0 or higher Variable is automatically set to 256)<br />
Type: switch mode (R/W) Units: bits<br />
Range: 1, 2, 4, 8, 16, 32, 64,128,256<br />
(Endat encoders in 3.4 firmware)<br />
Default: 256 EEPROM: Yes<br />
256 only (for All other sine encoders) Opmodes: All Drive Status: DIS<br />
MSINFRQ<br />
MSINFRQ is used with the sine encoder option <strong>and</strong> sets the maximum frequency limit of the encoder equivalent<br />
output. If the encoder equivalent output exceeds the value set by this variable, it becomes inaccurate <strong>and</strong> a burst<br />
overflow fault is generated.<br />
0 = ignore burst overflow fault<br />
1 = 2.5 MHz<br />
2 = 1.25 MHz<br />
3 = 625 KHz<br />
4 = 312 KHz<br />
Firmware Versions: 3.3.0 <strong>and</strong> higher Type: switch mode (R/W) Units: N/A<br />
Range: 0 to 4 Default: 1 EEPROM: Yes<br />
Opmodes: All Drive Status: DIS<br />
MSPEED<br />
Defines the maximum recommended velocity of the Motor. When this variable is changed, the drive enters a nocomp<br />
state, requiring a CONFIG comm<strong>and</strong> (see CONFIG).<br />
Firmware Versions: All Type: variable (R/W) Units: rotary: RPM<br />
Range: 10 to 32767 Default: motor data linear: mm/sec<br />
Opmodes: All Drive Status: DIS EEPROM: Yes<br />
MTANGLC<br />
Sets the value of the torque-related commutation angle advance at the motor’s continuous current rating<br />
(MICONT). This variable helps increase reluctance torque. For surface magnet motors, a typical value is 5. For<br />
motors with embedded magnets, a typical value is 8 to 10.<br />
Firmware Versions: All Type: variable (R/W) Units: electrical degrees<br />
Range: 0 to 45 Default: 10 EEPROM: Yes<br />
Opmodes: All Drive Status: EN/DIS<br />