O1RST<br />

A variable used to define the reset level for O1MODE. Range is dependent on O1MODE:<br />

0 - N/A<br />

1 - N/A<br />

2 - N/A<br />

3 - N/A<br />

4 - Absolute: 0 - 15000 RPM (0 - 250*MPITCH mm/sec for linear)<br />

5 - Absolute: 0 - 15000 RPM (0 - 250*MPITCH mm/sec for linear)<br />

6 - N/A<br />

7 - N/A<br />

8 - N/A<br />

9 - (-2,147,483,647) to 2,147,483,647 counts<br />

10 - N/A<br />

Firmware Versions: 2.1.0 <strong>and</strong> later Type: variable (R/W) Units: RPM or mm/sec<br />

Range: 0 to 10 (see above) Default: VOSPD EEPROM: Yes<br />

Opmodes: All Drive Status: EN/DIS<br />

O1TRIG<br />

A variable used to define the trip level for O1MODE. Range is dependent on O1MODE:<br />

0 - N/A<br />

1 - Absolute: 0 to 15000 RPM (mm/sec for linear motors)<br />

2 - Absolute: 0 to 1000 (0.1 percent of DIPEAK)<br />

3 - N/A<br />

4 - Absolute: 0 to 15000 RPM (mm/sec for linear motors)<br />

5 - N/A<br />

6 - N/A<br />

7 - N/A<br />

8 - Absolute: 0 to 15000 RPM (mm/sec for linear motors)<br />

9 - (-2,147,483,647) to 2,147,483,647 counts<br />

10 - N/A<br />

Firmware Versions: 2.1.0 <strong>and</strong> later Type: variable (R/W) Units: see above<br />

Range: 0 to 10 (see above) Default: 1000 EEPROM: Yes<br />