DIR<br />
Sets the direction (inversion) of many different parameters with respect to the rotation of the motor; as viewed<br />
looking at the end of the shaft.<br />
Variable Syntax: DIR <br />
This variable switch was greatly exp<strong>and</strong>ed for SERCOS use with the introduction of<br />
firmware version 3.4.0. Historically, it was a two-position switch with the following<br />
definition:<br />
0 = positive motion is counter-clockwise (CCW)<br />
1 = positive motion is clockwise (CW)<br />
For Non-SERCOS Users:<br />
Only the first parameter should be used to affect performance; <strong>and</strong> even then, only the parameters 0 or 1.<br />
Therefore, the st<strong>and</strong>ard user need only configure the first parameter (0 for CCW <strong>and</strong> 1 for CW) to control All<br />
three loops simultaneously. If you query the variable, All three parameters are communicated even though only<br />
one was changed. Just leave the second <strong>and</strong> third at their default settings.<br />
Parameter Position Velocity Torque<br />
0 1 1 1<br />
1 0 0 0<br />
For SERCOS Users:<br />
The SERCOS interface only affects the position comm<strong>and</strong> <strong>and</strong> position feedback polarities.<br />
First Parameter: sets the direction (inversion) of the Position comm<strong>and</strong>, Velocity comm<strong>and</strong>, <strong>and</strong> Torque<br />
comm<strong>and</strong>.<br />
Parameter Position Velocity Torque<br />
0 1 1 1<br />
1 0 0 0<br />
2 0 1 0<br />
3 0 1 1<br />
4 1 0 0<br />
5 1 0 1<br />
6 1 1 0<br />
7 0 0 1<br />