Required RECTRIG Parameters Based on MODE Parameter<br />

MODE DESCRIPTION LEV LOC DIR<br />

“IA Trigger on Phase A Current √ √ √<br />

“IC Trigger on Phase C Current √ √ √<br />

“ICMD Trigger on Current Cmd √ √ √<br />

“PCMD* Trigger on Position Cmd √ √ √<br />

“PFB* Trigger on Position Fdback √ √ √<br />

“PRD Trigger on PRD √ √ √<br />

“V Trigger on Velocity √ √ √<br />

“VCMD Trigger on Velocity Cmd √ √ √<br />

“CCW Trigger on CCWLIM Sw X √ √<br />

“CW Trigger on CWLIM Sw X √ √<br />

“IN1* Trigger on IN1 Input X √ √<br />

“IN2* Trigger on IN1 Input X √ √<br />

“IN3* Trigger on IN1 Input X √ √<br />

“O1* Trigger on O1 Output X √ √<br />

“RMT Trigger on REMOTE Input X √ √<br />

“CMD Trigger on Next Comm<strong>and</strong> X √ X<br />

“IMM Trigger Immediately X X X<br />

* = firmware versions 3.2.0 <strong>and</strong> later<br />

√ = Required Parameter<br />

X = Don’t care. Something must be entered to make the comm<strong>and</strong> work, but it does not matter what is entered.<br />

Syntax:RECTRIG [mode] [level] [location] [direction]<br />

Firmware Versions: All Example: RECORD 10 100 “VCMD “V “PRD<br />

(record 100 points for VCMD, V, <strong>and</strong> PRD every 5 milliseconds)<br />

Range/Units: [mode]:see table above<br />

[level]: depends upon the mode variable (range of PRD levels is 0-65535. All others are -32768 to 32767)<br />

[location]: 0 - 1023<br />

[direction]: 0 or 1<br />

Type: variable (R/W)<br />

Default: [level]: 0<br />

[location]: 0<br />

Opmodes: All<br />

[direction]: 1<br />

EEPROM: No Drive Status: EN/DIS<br />

REFRESH<br />

A comm<strong>and</strong> used when tuning the drive for COMPMODE 3. With the Advanced Pole Placement algorithm<br />

utilized in the drive, the interaction of the variables is too dramatic to Allow variables to be changed one by one.<br />

Therefore, as pole placement algorithm vector variables (VD, VF, VH, <strong>and</strong> VR) are entered, the new values are<br />

buffered without changing the actual values used by the control loops.<br />

Once all desired new values have been entered, you enter a REFRESH comm<strong>and</strong>, <strong>and</strong> all vector variables are<br />

written to the control loops simultaneously.<br />

Firmware Versions: All Comm<strong>and</strong> Syntax: REFRESH<br />

Opmodes: 0, 1 Drive Status: EN/DIS<br />