Dumps a list of valid comm<strong>and</strong>s <strong>and</strong> variables to the serial port. Only the names of variables are transmitted,<br />

not values. Note that some factory variables <strong>and</strong> comm<strong>and</strong>s, not intended for use by the user, may be printed.<br />

Do not use comm<strong>and</strong>s <strong>and</strong> variables that are not described in this guide.<br />

Firmware Versions: All Comm<strong>and</strong> Syntax: LIST<br />

Opmodes: All Drive Status: EN/DIS<br />

LMJR<br />

Sets the ratio of the estimated Load Moment of Inertia (LMJ) relative to the Motor Moment of Inertia (MJ).<br />

The variables LMJR <strong>and</strong> MJ <strong>and</strong> the required closed loop b<strong>and</strong>width (BW) are used for the Velocity Control<br />

Loop design in the St<strong>and</strong>ard Pole-Placement controller (COMPMODE = 2 or 4). Executing the TUNE<br />

comm<strong>and</strong> successfully may change the value of this parameter.<br />

Firmware Versions: All Type: variable (R/W) Units: percent of MJ<br />

Range: 0 to 10,000 Default: 0 EEPROM: Yes<br />

Opmodes: All Drive Status: EN/DIS<br />

LOAD<br />

Loads all variables saved in the EEPROM into system RAM. This comm<strong>and</strong> is automatically executed on<br />

power-up.<br />

Firmware Versions: All Comm<strong>and</strong> Syntax: LOAD<br />

Opmodes: All Drive Status: DIS<br />

LPFHZ1<br />

Sets the cutoff frequency of the first Low Pass Filter (LPF) used in the velocity loop. This variable only affects<br />

the system when FILTMODE = 1 or 2.<br />

Firmware Versions: All Type: variable (R/W) Units: Hz<br />

Range: 20 to 800, steps of 20 (20, 40, ..., 800) Default: 500 EEPROM: Yes<br />

Opmodes: 0,1,4,8 Drive Status: EN/DIS<br />

LPFHZ2<br />

Sets the cutoff frequency of the second Low Pass Filter (LPF) used in the velocity loop. This variable only<br />

affects the system when FILTMODE = 2.<br />

Firmware Versions: All Type: variable (R/W) Units: Hz<br />

Range: 20 to 800, steps of 20 (20, 40, ..., 800) Default: 500 EEPROM: Yes<br />

Opmodes: 0,1,4,8 Drive Status: EN/DIS<br />