Default Values<br />

PCMDMODE = 0 PEMAX = 0 PLIM = 0 PMAX = 2,000,000,000 PMIN = 2,000,000,000<br />

PROFMODE = 0 PROFSCRV = 50 PROMPT = 1 RELAYMODE = 0 SININTOUT = 1<br />

STOPPED = 0 TF = 100 THERMODE = 0 THERMTIME = 30 THERMTYPE = 0<br />

UNITS = 0 UVMODE = 0 UVTIME = 30 UVRECOVER = 0 VD = 0<br />

VF = 1,000,000 VH = 0 VLIM = VMAX VOSPEED = 1.2 * VLIM VR = 0<br />

XENCDIR = 0 XENCRES = 1024<br />

Firmware Versions: All Comm<strong>and</strong> Syntax: RSTVAR<br />

Opmodes: 0, 1 Drive Status: DIS<br />

S<br />

Stops motor motion in all OPMODES. Deceleration ramp control is always used, using the rate specified by<br />

DECSTOP. After the profile generator reaches 0 speed, the drive waits for the time period specified by<br />

DISTIME <strong>and</strong> disables the drive.<br />

This comm<strong>and</strong> is a one-key hot button, similar to the K comm<strong>and</strong>, but with an active stop function controlled by<br />

the drive (no coasting of the motor occurs, as is possible with the K comm<strong>and</strong>).<br />

Firmware Versions: All Comm<strong>and</strong> Syntax: S<br />

Opmodes: 0, 1 Drive Status: EN/DIS<br />

SAVE<br />

Copies all system configuration variables from working RAM to non-volatile memory (EEPROM). This<br />

comm<strong>and</strong> must be executed in order to retain setting changes during power cycling. The SAVE comm<strong>and</strong> takes<br />

about 2 seconds to execute.<br />

Firmware Versions: All Comm<strong>and</strong> Syntax: SAVE<br />

Opmodes: 0, 1 Drive Status: EN/DIS<br />

SERIALNO<br />

Indicates the serial number of the drive in which the firmware is installed. This variable is password protected.<br />

This variable is included in the VER string.<br />

Firmware Versions: All Type: string variable (R) Units: N/A<br />

Range: 10 ASCII characters Default: blanks EEPROM: Yes<br />

Opmodes: All Drive Status: EN/DIS<br />

SININTOUT<br />

Sets an interpolation factor of the sine encoder board for the equivalent encoder output. For sine encoder<br />

systems, the encoder output value (ENCOUT) = MENCRES * SININTOUT / ENCOUTO.<br />

Firmware Versions: 3.3.0 <strong>and</strong> later Type: switch mode (R/W) Units: N/A<br />

Range: 1, 2, 4, 8, 16, 32, 64, 128 Default: 1 EEPROM: Yes<br />

Opmodes: All Drive Status: DIS<br />