5.1.7 Technical specificationsPGZ100 All-in-one PotentiostatRegulationCompliance voltage: ±30 VMaximum current output: ±1 APolarization voltage: ±15 VSlew rate: 10 MV/sRise time (100% signal) < 1µsBandwidth (-3dB): 800 kHzCurrent autorangingPotential autorangingVoltammetry (DC)Applied DC potential- Ranges: ±4, ±8, ±15 V- Best resolution: 125 µV- Accuracy: ±0.2% of rangeMeasured potential- Ranges: ±2, ±4, ±8, ±15 V- Resolution16 bits (0.003% of range)- Best resolution: 60 µV- Accuracy: ±0.2 % of range- Analog output: Yes- DC offset and gain; Yes for EISMeasured current- Ranges: 7 from ±1A to ±1µA- Best resolution: 30 pA- Resolution16 bits (0.003% of range)- Accuracy: ±0.2 % of range- Analog output: Yes- DC offset and gain: Yes for EISFilters- Automatic mode- Manual mode: 7 filters- Anti-oscillation filterScanning performances- Measurement period: 20 ms- Max. scan rate: 500 mV/s ( =10 mV/20 ms)- Min. scan rate: 125 µV/125sOhmic Drop Compensation (iR)Static manual & Static autoElectrochemical ImpedanceDynamic EIS (DC + AC)Max. frequency: 100 kHzMin. frequency: 1 mHzFrequencies/decade: 5, 10, 20Sine wave amplitude: 1 mV to 1 VRanges: 50 & 1000 mVResolution: 12.5 & 250 µVAccuracy: ±0.5% of rangeCurrent autorangingEIS distortion- Module: 1% + (0.02%/kHz)- Phase shift: 1° + (0.02°/kHz)Cell ConnectionsREF (Reference Electrode, RE)- BNC coaxial socket- Input impedance: 10¹² Ohm- Capacitance < 20 pFWORK (Working Electrode, WE)- PL259 coaxial socket- Output impedance: LowSENSE (For 4-poles measurements)- BNC coaxial socket- Input impedance: LowAUX (Auxiliary Electrode, CE)- PL259 coaxial socket- Output impedance: LowAdditional channel connectionsD/A OUT (Output )- BNC coaxial socket- Range: 0 - 5000 mV- Resolution: 1.2 mV- Accuracy ±0.05% of rangeA/D IN (Input)- BNC coaxial socket- Range: ±5000 mV- Resolution: 152.5 µV- Accuracy ±0.1% of range- Input impedance: 10 MOhm- Input synchronised with E & iVg IN (External Generator)- BNC coaxial socket - Range: ±10 V- Input impedance: 10 kOhmOther connectionsE OUT (Measured potential output)- BNC coaxial socket - Range ±15V- Accuracy: ±0.2%I OUT (Measured current output)- BNC coaxial socket - Range: ± 1V- Accuracy: ±0.2%- Linear with current range126VoltaLab 21/06/10/40/50/80Section 5, Chapter 1: The PGZ and PST series