13.07.2015 Views

Register your product now - Radiometer Analytical

Register your product now - Radiometer Analytical

Register your product now - Radiometer Analytical

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5.1.7 Technical specificationsPGZ100 All-in-one PotentiostatRegulationCompliance voltage: ±30 VMaximum current output: ±1 APolarization voltage: ±15 VSlew rate: 10 MV/sRise time (100% signal) < 1µsBandwidth (-3dB): 800 kHzCurrent autorangingPotential autorangingVoltammetry (DC)Applied DC potential- Ranges: ±4, ±8, ±15 V- Best resolution: 125 µV- Accuracy: ±0.2% of rangeMeasured potential- Ranges: ±2, ±4, ±8, ±15 V- Resolution16 bits (0.003% of range)- Best resolution: 60 µV- Accuracy: ±0.2 % of range- Analog output: Yes- DC offset and gain; Yes for EISMeasured current- Ranges: 7 from ±1A to ±1µA- Best resolution: 30 pA- Resolution16 bits (0.003% of range)- Accuracy: ±0.2 % of range- Analog output: Yes- DC offset and gain: Yes for EISFilters- Automatic mode- Manual mode: 7 filters- Anti-oscillation filterScanning performances- Measurement period: 20 ms- Max. scan rate: 500 mV/s ( =10 mV/20 ms)- Min. scan rate: 125 µV/125sOhmic Drop Compensation (iR)Static manual & Static autoElectrochemical ImpedanceDynamic EIS (DC + AC)Max. frequency: 100 kHzMin. frequency: 1 mHzFrequencies/decade: 5, 10, 20Sine wave amplitude: 1 mV to 1 VRanges: 50 & 1000 mVResolution: 12.5 & 250 µVAccuracy: ±0.5% of rangeCurrent autorangingEIS distortion- Module: 1% + (0.02%/kHz)- Phase shift: 1° + (0.02°/kHz)Cell ConnectionsREF (Reference Electrode, RE)- BNC coaxial socket- Input impedance: 10¹² Ohm- Capacitance < 20 pFWORK (Working Electrode, WE)- PL259 coaxial socket- Output impedance: LowSENSE (For 4-poles measurements)- BNC coaxial socket- Input impedance: LowAUX (Auxiliary Electrode, CE)- PL259 coaxial socket- Output impedance: LowAdditional channel connectionsD/A OUT (Output )- BNC coaxial socket- Range: 0 - 5000 mV- Resolution: 1.2 mV- Accuracy ±0.05% of rangeA/D IN (Input)- BNC coaxial socket- Range: ±5000 mV- Resolution: 152.5 µV- Accuracy ±0.1% of range- Input impedance: 10 MOhm- Input synchronised with E & iVg IN (External Generator)- BNC coaxial socket - Range: ±10 V- Input impedance: 10 kOhmOther connectionsE OUT (Measured potential output)- BNC coaxial socket - Range ±15V- Accuracy: ±0.2%I OUT (Measured current output)- BNC coaxial socket - Range: ± 1V- Accuracy: ±0.2%- Linear with current range126VoltaLab 21/06/10/40/50/80Section 5, Chapter 1: The PGZ and PST series

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!