4.3.13 Pot. Dynamic EIS (Impedance)Electrochemical Impedance Spectroscopy (EIS) is used to investigate the kineticsof electrochemical processes. A dynamic EIS experiment will generate a set ofindividual electrochemical impedance spectra obtained at different DC potentials.Each individual spectrum reports the impedances measured at various frequencieswith a superimposed AC signal on a given DC potential. Dynamic EIS programmingcan generate:- Frequency scan at a single DC potential- Frequency scans at specified time intervals (at a single DC potential)- Frequency scans at different DC potentials (from initial to final in pre-set potentialsteps)- Frequency scans at specified time intervals at OCP in between each EIS (sequencemade of a succession of OCP with polarisation at end and Pot. Tutorial EIS with DCpotential = Free and OCP at end)Nyquist or Bode diagrams are available as a real-time plot display. Method availablewith VoltaLab 40 and VoltaLab 80.Consult the Help file, keyword indexes:Pot. Dynamic EIS (Impedance) - Method editing and Pot. Dynamic EIS(Impedance) - Measurements and curve files.4.3.14 Pot. Expert EIS (Impedance)The Pot. Expert EIS (Impedance) method enables you to get more accurate resultsthan with the Pot. Tutorial or Dynamic EIS methods. This expert-dedicated methodallows to edit up to 3 segments along the frequency range with the followingappropriate parameters: Frequency scan limits, AC amplitude, Frequency resolution(Freq. per decade), Number of measurement repetitions or number of sine wavesupon which frequency is considered (Repeat meas.), Number of measurementstaken for the mean calculation (Average last), Delay before integration and ACcurrent measuring range.If you compare with the Pot. Dynamic EIS (Impedance) method, where all theparameters have been set to give you a spectrum as rapidly as possible, a Pot.Expert EIS method will deliver a better result because you will allow more time forstabilisation and integration when you need it.Only one file is generated. Method available with VoltaLab 40 and VoltaLab 80.Consult the Help file, keyword indexes:Pot. ExpertEIS (Impedance) - Method editing and Pot. Expert EIS (Impedance) -Measurements and curve files.VoltaMaster 4 - Version 7.0x 49Section 4, Chapter 3: Methods available

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!