PST050 <strong>Analytical</strong> PotentiostatRegulationCompliance voltage: ±30 VMaximum current output: ±1 APolarization voltage: ±15 VSlew rate: 10 MV/sRise time (100% signal) < 1µsBandwidth (-3dB): 800 kHzCurrent autorangingPotential autorangingVoltammetry (DC)Applied DC potential- Ranges: ±4, ±8, ±15 V- Best resolution: 125 µV- Accuracy: ±0.2% of rangeMeasured potential- Ranges: ±2, ±4, ±8, ±15 V- Resolution16 bits (0.003% of range)- Best resolution: 60 µV- Accuracy: ±0.2 % of range- Analog output: NoMeasured current- Ranges: 9 from ±1A to ±10nA (with gain)- Best resolution: 300 fA (with gain)- Resolution16 bits (0.003% of range)- Accuracy: ±0.2 % of range- Analog output: NoFilters- Automatic mode- Manual mode: 7 filters- Anti-oscillation filterScanning performances- Measurement period: 0.5 ms- Max. scan rate: 20 V/s ( =10 mV/0.5 ms)- Min. scan rate: 125 µV/125sOhmic Drop Compensation (iR)- Dynamic- Static manual & Static auto- Feedback manual & Feed back autoCell ConnectionsREF (Reference Electrode, RE)- BNC coaxial socket- Input impedance: 10¹² Ohm- Capacitance < 20 pFWORK (Working Electrode, WE)- PL259 coaxial socket- Output impedance: LowAUX (Auxiliary Electrode, CE)- PL259 coaxial socket- Output impedance: LowAdditional channel connectionsD/A OUT (Output )- BNC coaxial socket- Range: 0 - 5000 mV- Resolution: 1.2 mV- Accuracy ±0.05% of rangeA/D IN (Input)- BNC coaxial socket- Range: ±5000 mV- Resolution: 152.5 µV- Accuracy ±0.1% of range- Input impedance: 10 MOhm- Input synchronised with E & iOther connectionsFunctional ground- banana socket to connect a Faraday cageRS232C (Serial port)- SUB-D9 male socket to connect a PCGeneralPower supply- 120 V~ (±10%) or 230 V~ (±10%)50...60 Hz - 170 VA- On/Off power switchMains fuses- Type: TT2A L250V (2 fuses)Secondary fuses- Type : TT630mA (1 fuse), TT1A (3 fuses)and TT2A (2 fuses)Size & Weight- 485 x 300 x 88 mm & 13 kgEnvironmental conditions- Interior use only- Ambient temperature:working range: 5 to 40°Cstorage: -20 to 60°Ctransport: -40 to 60°C- Relative humidity: 20 to 80 % withtemperature between 5 and 31 °C, above31°C, the interval amplitude decreaseslinearly from 20 - 80% at 31°C to 20 - 50% at40°C.- Altitude ≤ 2000 m.- Level of pollution : 2- Transitory overvoltage: class IIVoltaLab 21/06/10/40/50/80 133Section 5, Chapter 1: The PGZ and PST series

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!