13.07.2015 Views

Register your product now - Radiometer Analytical

Register your product now - Radiometer Analytical

Register your product now - Radiometer Analytical

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4.6.2 Demonstration CurvesThe demonstration curves are located in C:\Program Files\VoltaLab\Demo Curvesif you have installed VoltaMaster 4 with the default values. These demonstrationcurves have been obtained with the VoltaLab 80 Universal ElectrochemicalLaboratory. Some methods cannot be run with a VoltaLab 50, VoltaLab 40,VoltaLab 10, VoltaLab 06 or VoltaLab 21. These curves are:Real experiments. Open Circuit Potential: Automatic recording of OCP .... Pot Cyclic Voltammetry: Pot. Cyclic voltammetry with or without ohmic dropcompensation. Pot. Cyclic Voltammetry: Pot. Cyclic Voltammetry with or without ohmic dropcompensation. Pot. Interactive CV: Scan rate CV interactive. Pot. Interactive CV: Vertex CV interactive. Pot. Dynamic EIS (Impedance): Faradaic and diffusion control. Gal. Tutorial EIS (Impedance): Corrosion study by Gal. Tutorial EIS (Impedance). Chrono Coulometry: Cottrell equation. Chrono Potentiometry: Reversibility of an electrochemical reaction. Pot. Fixed Freq. EIS (Capacitance): Measuring the capacitance versus potential. Pitting corrosion: Pitting test. General corrosion (Rp): Automatic recording of Rp versus time. Coupled corrosion (Evans): Galvanic corrosion Fe/Zn (Evans). Pot. Universal DP: VoltaLab Universal Differential Pulse method “LV, CAand DP in one go!”. Pot. Universal DP: Trace analysis with Hanging Mercury Drop Electrode. Gal. Logarithmic CV: Testing battery performances. Pot. Square WV: Trace analysis of Pb, Zn, Cu. Gal. Recurrent DP: Battery discharge with RI determination. Pot. Linear V: Polarisation curve of stainless steel. Pot. Linear V: Detection of Cu(I) using a rotating ring and disc electrode. Standard addition: Chloride Trace analysis with Hanging Mercury Drop ElectrodeExperiments with RCB200 Resistor Capacitor Box. Chrono Amperometry: with RCB200 (position A): Resolution and accuracy on10 µA current range. Pot. Linear V: with RCB200 (position B): Autoranging performances. Pot. Tutorial EIS (Impedance): with RCB200 (position C): Impedance and R1R2Cfitting. Chrono Amperometry: with RCB200 (position D): Time constant determinationConsult the Help file and relevant keyword indexes.80VoltaMaster 4 - Version 7.0xSection 4, Chapter 6: Processing curves to obtain results

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!