Rail Corporation New South Wales<br />
<strong>Rolling</strong> <strong>Stock</strong> <strong>PPP</strong> – <strong>Double</strong> <strong>Deck</strong> <strong>Trains</strong><br />
Maintenance Facility Works Specification<br />
<strong>Exhibit</strong> 7 - MFS v7.doc<br />
(b) equipped with a very large white board (approx four (4) metre wide face when<br />
fully opened);<br />
(c) lined and insulated against heat and noise; and<br />
(d) dust proofed; and<br />
(e) designed to comply with the requirements for people with disabilities, and<br />
conform with Australian Standard AS 1428 Part 2 Enhanced and Additional<br />
Requirements – Buildings and Facilities.<br />
4.1.7 Stores Area(s)<br />
<strong>PPP</strong> Co must provide a Stores Area(s) which include racking and shelving suited to fork lift<br />
truck handling to house the stock Maintenance Parts and Materials necessary to support<br />
the TLS Phase Activities. The Stores Area(s) are to be integral with the Maintenance<br />
Building.<br />
<strong>PPP</strong> Co must provide an air conditioned office within the Stores Area(s), sized and<br />
equipped for an appropriate heat load.<br />
4.1.8 Amenities Area(s)<br />
<strong>PPP</strong> Co must provide air-conditioned Amenities Area(s) as necessary as part of the<br />
Maintenance Building that include:<br />
(a) toilet facilities;<br />
(b) change rooms and showers; and<br />
(c) a meal room.<br />
The Amenities Area(s) shall be designed to comply with the requirements of people with<br />
disabilities and conform with Australian Standard AS 1428 Part 2 Enhanced and Additional<br />
Requirements – Buildings and Facilities.<br />
The Amenities Area(s) must be sized and equipped to meet the forecast workforce<br />
numbers projected by <strong>PPP</strong> Co and the associated heat load, and any related buildings<br />
must conform to the requirements of all applicable laws.<br />
4.1.9 Crew Amenities Area<br />
<strong>PPP</strong> Co must provide toilet and associated facilities that can be accessed by <strong>RailCorp</strong> staff<br />
and other authorised personnel close to the designated Handover Point(s) and Pick-up<br />
Point(s) for Sets and the Other Sets.<br />
4.1.10 <strong>RailCorp</strong> Office Area<br />
<strong>PPP</strong> Co shall provide air-conditioned office facilities located adjacent the <strong>PPP</strong> Co Office<br />
Area, integral with the Maintenance Building. These office facilities must be:<br />
v7 – 17/01/2011 Page 29 of 51