SIMEA <strong>Stato</strong> dell’arte <strong>energetica</strong> <strong>degli</strong> <strong>edifici</strong><br />

1.3.13. VisualDOE<br />

103<br />

Doc.No 20100610.SIMEA.MR.03<br />

Versione 1<br />

A Windows interface to the DOE-2.1E energy simulation<br />

program. Through the graphical interface, users construct a<br />

model of the building's geometry using standard block shapes,<br />

using a built-in drawing tool, or importing DXF files. Building<br />

systems are defined through a point-and-click interface. A library<br />

of constructions, fenestrations, systems and operating schedules<br />

is included, and the user can add custom elements as well.<br />

VisualDOE is especially useful for studies of envelope and<br />

HVAC design alternatives. Up to 99 alternatives can be defined<br />

for a single project. Summary reports and graphs may be printed directly from the program. Hourly reports<br />

of building parameters may also be viewed.<br />

1.3.13.1. Expertise Required<br />

Basic experience with Windows programs is important. Familiarity with building systems is desirable<br />

but not absolutely necessary. One to two days of training is also desirable but not necessary for those familiar<br />

with building modelling.<br />

1.3.13.2. Users<br />

1000+, US and 34 other countries.<br />

1.3.13.3. Audience<br />

Mechanical/electrical/energy engineers and architects working for architecture/engineering firms,<br />

consulting firms, utilities, federal agencies, research universities, research laboratories, and equipment<br />

manufacturers.<br />

1.3.13.4. Input<br />

Required inputs include floor plan, occupancy type, and location. These are all that is required to run a<br />

simulation. Typically, however, inputs include wall, roof and floor constructions; window area and type;<br />

HVAC system type and parameters; and lighting and office equipment power. Smart defaults are available<br />

for HVAC systems based on the building vintage and size. A library and templates are provided to greatly<br />

ease user input.<br />

1.3.13.5. Output<br />

Produces input and output summary reports that may be viewed on-screen, stored as PDF files, or<br />

printed. A number of graphs may be viewed and printed. These graphs can compare selected alternatives<br />

and/or selected hourly variables. Standard DOE-2.1E reports and hourly reports are available.<br />

1.3.13.6. Computer Platform<br />

Windows 95/98/NT/ME/2000/XP. 486 or better, 16MB+ RAM, 50MB hard drive space.<br />

1.3.13.7. Programming Language<br />

Visual Basic and Visual C++