SIMEA <strong>Stato</strong> dell’arte <strong>energetica</strong> <strong>degli</strong> <strong>edifici</strong><br />

1.2.20. EE4 CBIP<br />

41<br />

Doc.No 20100610.SIMEA.MR.03<br />

Versione 1<br />

Designed to demonstrate a building's compliance to the requirements of the<br />

Commercial Building Incentive Program (CBIP) performance path approach. EE4<br />

CBIP is offered by Natural Resources Canada's Office of Energy Efficiency to<br />

building owners and developers for the design and construction of new<br />

commercial and institutional buildings that use 25% less energy than similar<br />

buildings built to the requirements of the Model National Energy Code for<br />

Buildings (MNECB). EE4 CBIP may also be used to perform non-compliance<br />

energy analyses and thus to predict a building's annual energy consumption, and<br />

to assess the impact of design changes to the building.<br />

1.2.20.1. Expertise Required<br />

Basic understanding of Windows. Knowledge of building modelling. Engineering background helpful<br />

but not required.<br />

1.2.20.2. Users<br />

1000<br />

1.2.20.3. Audience<br />

Mechanical, building, energy engineers and architects working for consulting firms, building owners<br />

and/or designers; building and energy-code verifiers; CBIP application reviewers.<br />

1.2.20.4. Input<br />

Basic information, envelope components areas and characteristics, characteristics of the building's<br />

HVAC, lighting and service water heating systems.<br />

1.2.20.5. Output<br />

Energy consumption and energy cost of proposed design and CBIP reference building. Summary and<br />

detailed compliance reports.<br />

1.2.20.6. Computer Platform<br />

PC-compatible, Windows NT or Windows 95/98/2000 operating system, IBM 486 or Pentium 75 with<br />

at least 16 MB RAM, 40 MB free disk space, SVGA monitor with minimum 800 x 600 resolution.<br />

1.2.20.7. Programming Language<br />

Borland C++<br />

1.2.20.8. Strengths<br />

EE4 CBIP automatically generates a reference building to verify compliance to CBIP requirements<br />

using the performance path approach. EE4 CBIP can also be used in non-compliance mode to predict a<br />

building's annual energy consumption and energy cost. Includes default libraries of common building plants,<br />

systems, construction assemblies and materials, lighting elements, fenestration and operating schedules.