(ii) By equipping the UN pressure receptacle with a valve cap conforming to<br />

the requirements in ISO 11117 and Technical Corrigendum 1 (IBR, see § 171.7 <strong>of</strong> this<br />

subchapter). The cap must have vent-holes <strong>of</strong> sufficient cross-sectional area to evacuate<br />

the gas if leakage occurs at the valve;<br />

* * *<br />

(d) Non-refillable UN pressure receptacles. (1) When the use <strong>of</strong> a valve is<br />

prescribed, the valve must conform to the requirements in ISO 13340 (IBR, see § 171.7<br />

<strong>of</strong> this subchapter).<br />

package;<br />

(2) The receptacles must be transported as an inner package <strong>of</strong> a combination<br />

(3) The receptacle must have a water capacity not exceeding 1.25 L when used for<br />

a flammable or toxic gas or 50 liters for receptacles used to contain chemical under<br />

pressure; and<br />

(4) The receptacle is prohibited for Hazard Zone A material.<br />

* * * * *<br />

60. In § 173.302a, paragraph (a)(3) is amended to read as follows<br />

§ 173.302a Additional requirements for shipment <strong>of</strong> nonliquefied (permanent)<br />

compressed gases in specification cylinders.<br />

(a) * * *<br />

(3) DOT 39 DOT 39 cylinders. When the cylinder is filled with a Division 2.1<br />

material, the internal volume <strong>of</strong> the cylinder may not exceed 1.23 L (75 in 3 ) or 50 L<br />

(3050 in 3 ) for chemical under pressure.<br />