02.08.2013 Views

FONIX® FP35 Touch - Frye Electronics

FONIX® FP35 Touch - Frye Electronics

FONIX® FP35 Touch - Frye Electronics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

An Overview of the <strong>FP35</strong> <strong>Touch</strong> 13<br />

1.4 Optional Features for the <strong>FP35</strong><br />

Real-Ear Option<br />

You can order the <strong>FP35</strong> with the Real-Ear Option so that you can do tests on the<br />

hearing aid while it is in the client’s ear. It is then possible to individualize the<br />

fitting of a hearing aid—a necessary step since a coupler measurement can seldom<br />

tell the operator exactly what sound is received by the client. Many factors<br />

affect sound on its way to the eardrum. By measuring with a probe microphone,<br />

you will know what is really happening in your client’s ear.<br />

External Monitor Option<br />

This hardware option allows the connection of the <strong>FP35</strong> analyzer to an external<br />

monitor. When connected, the <strong>FP35</strong> displays on both its internal LCD monitor<br />

and the connected external monitor. Although the display is always only in two<br />

colors, most standard flat screen and VGA computer monitors can be used.<br />

IEC<br />

You can add the IEC (International Electrotechnical Commission) test sequence<br />

to your <strong>FP35</strong> analyzer. This automated sequence lets you test the performance<br />

of hearing aids in accordance with the IEC 118-7 standard. Both the 1994 and<br />

2005 versions of the standard are available.<br />

JIS<br />

An automated test sequence that follows the JIS standard, widely used in Japan.<br />

ANSI<br />

The ANSI 96 and ANSI 03 automated test sequences are available as an option<br />

on your <strong>FP35</strong>. They provide you with the means to quickly and accurately test a<br />

hearing aid in accordance with the ANSI S3.22 standard.<br />

CIC Option<br />

This option consists of a 0.4 cc CIC coupler and software correction factors. The<br />

CIC correction factors are available in the Coupler Mode by selecting the CIC<br />

coupler in the Coupler Menu.<br />

Audiometer Option<br />

This adds pure-tone air audiometric measurements to your <strong>FP35</strong> hearing aid<br />

analyzer. You can either take the measurements with insert earphones or with a<br />

sound field speaker. See Chapter 7 for more details.<br />

ISI<br />

An automated test sequence conforming to the Indian ISI IS-10775-1984 standard.<br />

Note: The <strong>FP35</strong> is fully upgradeable. These options can be added to an existing<br />

unit.