ISO 9001: 2008 Effective from 18.06.2012 RDSO/SPN/196/2012 Version 3.1.1<br />

Document Title : Specification <strong>of</strong> <strong>Train</strong> <strong>Collision</strong> <strong>Avoidance</strong> <strong>System</strong><br />

Annexure-X (Page 2 <strong>of</strong> 3)<br />

Indian Railways Driver Machine Interface (IRDMI) GUIDELINES<br />

1. The IRDMI shall have LCD <strong>for</strong> display & s<strong>of</strong>t-keys <strong>for</strong> operation. There shall be<br />

minimum 22 s<strong>of</strong>t keys (20 in use & 2 as spare <strong>for</strong> future requirements).<br />

2. The s<strong>of</strong>tware <strong>of</strong> IRDMI shall be verified & validated to Safety Integrity Level (SIL) -2<br />

<strong>of</strong> CENELEC or equivalent international standards.<br />

3. The display area shall be LCD Module having minimum 256 colours, display size <strong>of</strong><br />

10.4" (diagonal) and minimum 640x480 pixels. This shall be <strong>of</strong> industrial grade & as<br />

per Clause 13.0 <strong>of</strong> RDSO specification no. RDSO/SPN/196/2012 ver – 3.1.<br />

4. Overlay background will be black.<br />

5. Locations <strong>for</strong> displaying various in<strong>for</strong>mation on LCD screen have been marked on the<br />

layout. The details are as under:<br />

i. Location ‘A’ – Location <strong>for</strong> displaying current mode <strong>of</strong> the system.<br />

ii. Location ‘B’ – ‘<strong>System</strong> Fail’ in red colour text shall be displayed when system is<br />

faulty & ‘<strong>System</strong> Healthy’ in green colour text when system is healthy.<br />

iii. Location ‘C’ – ‘RFID tag missing – One/ both’ text in flashing red <strong>for</strong> 10 seconds<br />

shall be displayed in case <strong>of</strong> one/ both RFID tag missing/ damaged which will<br />

become steady & will remain till it finds next RFID tag. Normally, there shall be<br />

no display at this location.<br />

Below this Location, the Loco TCAS unit shall also display the Success Rate <strong>of</strong><br />

communication packets received from Stationary TCAS unit in Numeral and<br />

Graphical Bar <strong>for</strong>m.<br />

iv. Location ‘D’ to Location ‘L’ – The purpose <strong>of</strong> pressing the corresponding button<br />

(above the location) shall be displayed in text in yellow colour. The purpose <strong>of</strong><br />

pressing <strong>of</strong> some <strong>of</strong> the buttons may change as per the context <strong>of</strong> the situation<br />

as described below:<br />

a. Location ‘D’ – After switching on the system, ‘Start’ shall be displayed which<br />

will become flashing once the ‘Start’ button is pressed. Normally, there shall<br />

be no display at this location.<br />

b. Location ‘E’, ‘F’ & ‘G’ – For selection or toggling <strong>of</strong> various modes <strong>of</strong> Loco unit<br />

which are authorized to be selected manually. For example, one button could<br />

be used <strong>for</strong> ‘Reverse Mode’. The text below this button shall normally indicate<br />

‘Select’. On pressing this button, the Loco unit mode shall change to ‘Reverse<br />

Mode’ as per the specification, the display at Location ‘A’ shall display<br />

‘Reverse Mode’ & the text below this button shall now change to ‘Exit’ so that<br />

another pressing <strong>of</strong> this button shall cause exit from ‘Reverse Mode’.<br />

c. Location ‘H’ – The ‘Brightness’ button shall be used to activate/ deactivate<br />

brightness control <strong>of</strong> the screen. This button shall act as a toggle switch.<br />

Depending upon the function <strong>of</strong> this button, the text ‘Brightness Mode’ or<br />

‘Brightness exit’ in white colour shall be displayed at this location. When<br />

brightness control is activated, ↑& ↓ buttons shall be used to control the<br />

brightness.<br />

d. Location ‘J’ – The ‘Restricted’ button shall act as a toggle switch to per<strong>for</strong>m<br />

shunt request/ exit functions. Depending upon the function <strong>of</strong> this button, the<br />

text ‘Restricted Mode Request’ or ‘Restricted Mode Exit’ in yellow colour shall<br />

be displayed at this location.<br />

Signal Directorate RDSO/Lucknow Page 55 <strong>of</strong> 56