03.08.2013 Views

Tender invited for Development of Train Collision Avoidance System

Tender invited for Development of Train Collision Avoidance System

Tender invited for Development of Train Collision Avoidance System

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ISO 9001: 2008 Effective from 18.06.2012 RDSO/SPN/196/2012 Version 3.1.1<br />

Document Title : Specification <strong>of</strong> <strong>Train</strong> <strong>Collision</strong> <strong>Avoidance</strong> <strong>System</strong><br />

design / configuration and shall be approved by RDSO (the various tests<br />

parameter <strong>for</strong> card level test, system level functional test, diagnostic test and<br />

per<strong>for</strong>mance test shall be specified <strong>for</strong> inclusion in the specification).<br />

15.3 Verification & Validation <strong>of</strong> the s<strong>of</strong>tware and hardware shall be done by<br />

independent assessor as per Safety Integrity Level – 4 (SIL-4) <strong>of</strong> CENELEC<br />

standards or equivalent. Further a comprehensive report from the V&V<br />

consultant, covering full terms <strong>of</strong> reference should be submitted to RDSO <strong>for</strong><br />

final assessment.<br />

16. Tests and Verification<br />

16.1 The test procedure shall be based on the system design. The methodologies to<br />

be adopted <strong>for</strong> various tests shall be decided taking into account the system<br />

design/ configuration and shall be approved by the RDSO.<br />

16.2 The following sequence <strong>of</strong> tests shall be conducted:<br />

• Type tests;<br />

• Acceptance tests;<br />

• Routine Tests;<br />

• <strong>System</strong> acceptance tests;<br />

• Integration Tests;<br />

16.3 Type Tests<br />

16.3.1 Following tests shall constitute type tests:<br />

a) Visual inspection.<br />

b) Insulation Resistance tests<br />

c) Applied high voltage tests<br />

d) Card level/ module level check<br />

e) Card-level functional tests one card <strong>of</strong> each type.<br />

f) <strong>System</strong> level functional tests/ per<strong>for</strong>mance tests<br />

g) Environmental / climatic tests.<br />

h) Vibration tests, abrasive environment tests.<br />

i) <strong>System</strong> Diagnostics test.<br />

j) Any other tests as considered necessary by the purchaser.<br />

k) Integration Tests: Integration tests to integrate the various sub-systems <strong>of</strong><br />

the TCAS and demonstrate correct operation <strong>of</strong> all internal and external<br />

interfaces.<br />

16.3.2 Only one each equipment shall be tested <strong>for</strong> this purpose. The equipment<br />

shall successfully pass all the type tests <strong>for</strong> proving con<strong>for</strong>mity with this<br />

specification. If the equipment fails in any <strong>of</strong> the type tests, the purchaser or<br />

his nominee at his discretion may call <strong>for</strong> another equipment/ card(s) <strong>of</strong> the<br />

same type and subject it to all tests or to the test(s) in which failure occurred.<br />

No failure shall be permitted in the repeat test(s).<br />

16.4 Acceptance Tests<br />

Following shall comprise acceptance tests:<br />

a) Visual inspection.<br />

b) Insulation Resistance tests<br />

c) Applied high voltage tests<br />

d) Card level/ module level check.<br />

e) Card-level functional test on all the cards.<br />

f) <strong>System</strong> level functional tests/ per<strong>for</strong>mance tests.<br />

g) <strong>System</strong> Diagnostics test.<br />

16.5 Routine Tests<br />

Following shall comprise the routine tests and shall be conducted by<br />

manufacturer on each equipment and the test results will be submitted to the<br />

inspection authority be<strong>for</strong>e inspection. The validation report <strong>of</strong> application<br />

s<strong>of</strong>tware in proper <strong>for</strong>mat shall also be submitted to the inspection authority in<br />

advance.<br />

Signal Directorate RDSO/Lucknow Page 38 <strong>of</strong> 56