Compact / CANmotion /Motion Controller ... - Schneider Electric
Compact / CANmotion /Motion Controller ... - Schneider Electric
Compact / CANmotion /Motion Controller ... - Schneider Electric
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Brake<br />
settings<br />
1 The r2 relay output is used for brake control.<br />
2 To assign the r2 relay output :<br />
Select FUn-<br />
[APPLICATION<br />
FUNCT.] and press<br />
enter<br />
Select bLC- [BRAKE<br />
LOGIC CONTROL]<br />
and press enter<br />
Select bLC [BRAKE<br />
ASSIGNMENT] and<br />
press enter<br />
Select r2 and press<br />
enter.<br />
Set the parameters to the<br />
values shown here on the<br />
right.<br />
Note:<br />
These parameters are for the<br />
test machine only. They are<br />
NOT VALID for every<br />
machine.<br />
After all parameters are set<br />
return to the bLC with ESC.<br />
Return to the bLC- with ESC.<br />
Return to the FUn with ESC.<br />
Performance <strong>CANmotion</strong> LMC058 <strong>Schneider</strong> <strong>Electric</strong> 127