Notes<br />

The components designed for installation in a cabinet, i.e. the controller, safety modules,<br />

circuit breakers, contactors, motor circuit breakers, power supply, TeSysU motor starter<br />

and Adantys OTB I/O modules can be mounted on a 35 mm DIN rail.<br />

The Magelis XBTGT HMI is mounted on the cabinet’s door.<br />

Main switch, solid state relay, Lexium 32A servo drives, Lexium SD3 stepper drives and<br />

Altivar variable speed drives are screwed directly onto the mounting plate. Alternatively the<br />

Altivar 312 and Lexium SD3 can be mounted on a DIN rail, if an adapter is used.<br />

The ILA and ILE integrated drives Lexium and the OsiSense (Osicoder) CANopen encoder<br />

are installed in the field.<br />

The Emergency Stop button, the door guard switches and the pushbutton housing for the<br />

display and acknowledgement indicators are designed for on-wall mounting in the field. All<br />

switches (except the door guard switch) can also be installed directly in a control cabinet<br />

(e.g., in a cabinet door) without special housings.<br />

There are two options for installing XB5 pushbuttons or indicator lamps: These<br />

pushbuttons or switches can be installed either in a 22 mm hole, e.g., drilled into the front<br />

door of the control cabinet, or in an XALD-type housing suitable for up to 5 pushbuttons or<br />

indicator lamps.<br />

The XALD pushbutton housing is designed for backplane assembly or direct wall mounting<br />

400 Vac 3-phase wiring for the main circuit breaker, drives, stepper drives, motor starter<br />

and motors.<br />

230 Vac 1-phase wiring between the main circuit breaker and Lexium drives.<br />

230 Vac 1-phase wiring between the main circuit breaker and primary side of the 24 Vdc<br />

power supply.<br />

24 Vdc wiring for control circuits and the controller power supply, I/O modules, HMI and<br />

integrated drives Lexium.<br />

The individual components must be interconnected in accordance with the detailed circuit<br />

diagram in order to ensure that they function correctly.<br />

CANopen cables are installed for the communications link between the controller and the,<br />

Lexium 32A, Lexium SD3, Altivar 71, Altivar 312, TeSysU, ILA & ILE integrated Lexium<br />

dives, OsiSense (Osicoder) and Advantys OTB I/O modules.<br />

Ethernet cables are installed for the communications link between the controller and the<br />

HMI.<br />