Notes<br />
The components designed for installation in a cabinet, i.e. the controller, safety modules,<br />
circuit breakers, contactors, motor circuit breakers, power supply, TeSysU motor starter<br />
and Adantys OTB I/O modules can be mounted on a 35 mm DIN rail.<br />
The Magelis XBTGT HMI is mounted on the cabinet’s door.<br />
Main switch, solid state relay, Lexium 32A servo drives, Lexium SD3 stepper drives and<br />
Altivar variable speed drives are screwed directly onto the mounting plate. Alternatively the<br />
Altivar 312 and Lexium SD3 can be mounted on a DIN rail, if an adapter is used.<br />
The ILA and ILE integrated drives Lexium and the OsiSense (Osicoder) CANopen encoder<br />
are installed in the field.<br />
The Emergency Stop button, the door guard switches and the pushbutton housing for the<br />
display and acknowledgement indicators are designed for on-wall mounting in the field. All<br />
switches (except the door guard switch) can also be installed directly in a control cabinet<br />
(e.g., in a cabinet door) without special housings.<br />
There are two options for installing XB5 pushbuttons or indicator lamps: These<br />
pushbuttons or switches can be installed either in a 22 mm hole, e.g., drilled into the front<br />
door of the control cabinet, or in an XALD-type housing suitable for up to 5 pushbuttons or<br />
indicator lamps.<br />
The XALD pushbutton housing is designed for backplane assembly or direct wall mounting<br />
400 Vac 3-phase wiring for the main circuit breaker, drives, stepper drives, motor starter<br />
and motors.<br />
230 Vac 1-phase wiring between the main circuit breaker and Lexium drives.<br />
230 Vac 1-phase wiring between the main circuit breaker and primary side of the 24 Vdc<br />
power supply.<br />
24 Vdc wiring for control circuits and the controller power supply, I/O modules, HMI and<br />
integrated drives Lexium.<br />
The individual components must be interconnected in accordance with the detailed circuit<br />
diagram in order to ensure that they function correctly.<br />
CANopen cables are installed for the communications link between the controller and the,<br />
Lexium 32A, Lexium SD3, Altivar 71, Altivar 312, TeSysU, ILA & ILE integrated Lexium<br />
dives, OsiSense (Osicoder) and Advantys OTB I/O modules.<br />
Ethernet cables are installed for the communications link between the controller and the<br />
HMI.<br />
Performance <strong>CANmotion</strong> LMC058 <strong>Schneider</strong> <strong>Electric</strong> 19