06.08.2014 Views

(8.5x11) 6000 Manual Cover - Newport Corporation

(8.5x11) 6000 Manual Cover - Newport Corporation

(8.5x11) 6000 Manual Cover - Newport Corporation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

(LOCAL)<br />

SHIFT<br />

STO REF<br />

DISP<br />

REF SEL<br />

FILTER<br />

λ<br />

ZERO<br />

RANGE<br />

AUTO<br />

CH A<br />

CH B<br />

O<br />

I<br />

EXT<br />

R/S<br />

MENU<br />

MODE<br />

ENTER<br />

UNITS<br />

ESC<br />

STATS<br />

R/S A<br />

R/S B<br />

Figure 3 – Front Panel Key Pad<br />

Table 2 – Top Level Key Functions and Associated Remote Commands<br />

Keypad Remote Commands Description<br />

O I<br />

None Turns the Model 2832-C on and off.<br />

(LOCAL)/ None If the meter is in the remote mode,<br />

SHIFT<br />

depressing this key puts the meter into<br />

the local mode. Also, this key enables the<br />

blue key functions.<br />

DISP DISP, DISP? Cycles display brightness:<br />

OFF,LOW,NORM and HIGH.<br />

FILTER FILTER_n, FILTER_n? Cycles signal filtering:<br />

OFF, ANLG, DIG and ANLG+DIG.<br />

ZERO ZERO_n, ZERO_n?, Zeroes the display via offset subtraction.<br />

STOZERO_n, ZEROVAL_n?<br />

AUTO AUTO_n, AUTO_n? Turns automatic gain ranging on and off.<br />

CH A DISPCH, DISPCH? Selects channel A as the primary display<br />

channel.<br />

CH B DISPCH, DISPCH? Selects channel B as the primary display<br />

channel.<br />

STO REF STOREF_n, STOREF_n? Stores last reading for future dB and<br />

REL measurements.<br />

REF SEL REFSEL_n, REFSEL_n? Selects the reference source to be used<br />

for dB and REL measurements.<br />

λ LAMBDA_n, LAMBDA_n? Displays and edits the calibration<br />

wavelength in use.<br />

RANGE RANGE_n, RANGE_n? Displays signal gain range in use.<br />

, None Adjusts gain range or parameter<br />

values or moves through a list.<br />

R/S RUN, STOP Toggles the signal acquisition of<br />

both channels.<br />

MODE MODE_n, MODE_n? Cycles meter between allowed<br />

measurement modes.<br />

UNITS UNITS_n, UNITS_n? Cycles display measurement units<br />

between those allowed.<br />

STATS<br />

STSIZE_n, STSIZE_n?, STMAX_n? Displays statistics.: Max, Min,<br />

STMIN_n?, STMXMN_n? Max-Min, Mean and Std. Dev.<br />

STMEAN_n, STSDEV_n?<br />

R/S A RUN_A, RUN_A? Starts and stops channel A signal<br />

acquisition.<br />