SOFT STARTERS<br />

MVX Soft Starter<br />

Overview<br />

The MVX provides compact and robust soft start solutions for control of medium voltage motors. MVX soft starters<br />

provide a complete range of motor and system protection features and have been designed for reliable performance<br />

in the most demanding installation situations.<br />

Each MVX soft starter comprises:<br />

a Phase Cassette<br />

a Controller module<br />

The Phase Cassette and Controller module are supplied as a pair and share the same serial number. Care should be<br />

taken during installation to ensure the correct Controller and Phase Cassette are used together.<br />

Feature List<br />

NOTE<br />

Fibre-optic cables are only supplied in IP00 variants of the MVX soft starter. In all other MVX soft<br />

starters, this is part of the main assembly.<br />

Starting<br />

Constant current<br />

Current ramp<br />

Stopping<br />

Coast to stop<br />

Soft stop<br />

Protection<br />

Under/ Overvoltage<br />

Mains frequency<br />

Phase sequence<br />

Shorted SCR<br />

Motor overload (thermal model)<br />

Instantaneous overcurrent<br />

Time-overcurrent<br />

Ground fault<br />

Undercurrent<br />

Current imbalance<br />

Motor thermistor<br />

Excess start time<br />

Power circuit<br />

Auxiliary trip<br />

Extensive input and output options<br />

Remote control inputs<br />

(3 x fixed, 2 x programmable)<br />

Relay outputs<br />

(3 x fixed, 3 x programmable)<br />

Analog output<br />

(1 x programmable)<br />

Serial port<br />

Comprehensive feedback<br />

Digital display with multi-language support<br />

Controller buttons for quick access to common tasks<br />

Starter status LEDs<br />

Date and time stamped event logging<br />

Operational counters (starts, hours-run, kWh)<br />

Performance monitoring (current, voltage, power factor,<br />

kWh)<br />

User-programmable monitoring screen<br />

Multi-level password protection<br />

Emergency stop<br />

Power Connection<br />

15 A to 800 A, nominal<br />

2200 VAC to 11000 VAC<br />

Accessories (optional)<br />

DeviceNet, Modbus, Profibus or USB communication<br />

interfaces<br />

PC Software<br />

RTD relay<br />

Motor Protection Relay<br />

Predictive Maintenance Module (PMM)<br />