Now find the 25mm hole and maximise the signal, turning it to 100%FSH.<br />

Move the probe to either side of the hole marking the centre of the probe<br />

on the side of the block where the signal drops by 20dB.<br />

Measure 25mm on the paper and use the distances on the block to plot the<br />

beam dimensions at 25mm.<br />

Repeat using the 32mm hole. Join up the points marking the probe centre<br />

at 20dB to obtain a beam plot.