Q3-11 When using a focued, straight beam search unit <strong>for</strong> lamination<br />

scanning in an immersion test of steel plate, a change in water path of 0.2”<br />

will result in the focal point moving in the steel a distance of?<br />

Answer: The change in water path=0.2” correspond to 0.2 x 1483/5900 = 0.05”<br />

Q3-12 A search unit with a foal length in water of 4” is used. A steel plate 8”<br />

thick velocity 0.230”/ms is place at a water depth of 2” from the search unit, At<br />

what depth is the focal point in steel?<br />

Answer: Focal depth in steel = 2 x V water / V steel = 2x1480/5900 = 0.5”