Pulse Length:<br />

A sound pulse traveling through a<br />

metal occupies a physical<br />

volume. This volume changes<br />

with depth, being smallest in the<br />

focal zone. The pulse volume, a<br />

product of a pulse length L and a<br />

cross-sectional area A, can be<br />

fairly easily measured by<br />

combining ultrasonic A-scans and<br />

C-scans, as will be seen shortly.<br />

For many cases of practical interest, the inspection simulation models predict<br />

that S/N (signal to noise ratio) is inversely proportional to the square root of the<br />

pulse volume at the depth of the defect. This is known as the “pulse volume<br />

rule-of-thumb” and has become a guiding principle <strong>for</strong> designing<br />

inspections. Generally speaking, it applies when both the grain size and the<br />

lateral size of the defect are smaller than the sound pulse diameter.<br />

http://www.cnde.iastate.edu/ultrasonics/grain-noise