Q5: What is the maximum PRR is needed <strong>for</strong> contact test of steel material<br />

with 100 mm thick using longitudinal wave. Minimum number of hits<br />

required is 10. (VL, steel = 0.59 cm/μs )<br />

Answer:<br />

Distance = 100 x 2 =200mm <strong>for</strong> single loop.<br />

Effective distance D eff = 200 x10 =2000 mm<br />

Time = D eff / Velocity = 1/2950<br />

PRR = 1/T = 2950