43. When adjusting the flaw locating rule <strong>for</strong> a shear wave weld inspection,<br />

the zero point on the rule must coincide with the:<br />

A. Sound beam exit point of the wedge<br />

B. Point directly over the flaw<br />

C. Wheel transducer<br />

D. Circular scanner<br />

44. A special scanning device with the transducer mounted in a tire-like<br />

container filled with couplant is commonly called:<br />

A. A rotating scanner<br />

B. An axial scanner<br />

C. A wheel transducer<br />

D. A circular scanner