Miniature Resolution Block<br />

The miniature resolution block is used to evaluate the near-surface resolution<br />

and sensitivity of a normal-beam setup It can be used to calibrate highresolution<br />

thickness gages over the range of 0.015 inches (0.381 mm) to<br />

0.125 inches (3.175 mm).