39. In immersion testing in a small tank, a manually operated manipulator is<br />

use to:<br />

A. Set the proper water path<br />

B. Set the proper transducer angle<br />

C. Set the proper index function<br />

D. Complete both A and B<br />

40. In straight (normal) beam contact testing, a reduction in the back surface<br />

reflection amplitude could indicate:<br />

A. Inadequate coupling<br />

B. A flaw which is not normal to the beam<br />

C. A near surface defect that cannot be resolved from the main bang (initial<br />

pulse)<br />

D. All of the above