Q7: A steel plate size 6.2 m ×1.8 m ×0.1m is scanned using 25 mm<br />

diameter normal probe and overlap between scan is 20%. Minimum<br />

number of hits required is 15. Calculate the inspection time if scanning<br />

speed is 500 mm/s.<br />

Answer: (Standard Answer)<br />

Effective area of probe = 25 x0.8 x 500 = 10000 mm 2<br />

Area of plate = 6200 x 1800 mm 2<br />

T = (6200 x 1800)/ 10000 = 1116 s<br />

20% overlap<br />

25mm<br />

Effective area = 25 x 500 x<br />

0.8 = mm 2<br />

Scanning speed 500 mm/s