4.2.8.1: Linearity of time base<br />

General<br />

This check may be carried out using a standard calibration block eg A2,<br />

and a compressional wave probe. The linearity should be checked over a<br />

range at least equal to that which is to be used in subsequent testing.<br />

Method<br />

a) Place the probe on the 25mm thickness of the A2 block and adjust the<br />

controls to display ten BWEs.<br />

b) Adjust the controls so that the first and last BWEs coincide with the scale<br />

marks at 1 and 10.<br />

c) Increase the gain to bring successive backwall echoes to 80% FSH. The<br />

leading edge of each echo should line up with the appropriate reticules<br />

line.<br />

d) Record any deviations at approximately half screen height. Deviations<br />

should be expressed as a percentage of the range between the first and<br />

last echoes displayed (ie 225mm).