Q164: The resolving power of a transducer is directly proportional to its:<br />

A. Diameter<br />

B. Bandwidth<br />

C. Pulse repetition rate<br />

D. None of the above<br />

Bandwidth is the frequency range of the pulse, it is not the pulse length