09.09.2014 Views

Preparatory Notes for ASNT NDT Level III Examination - Ultrasonic Testing, UT

Preparatory Notes for ASNT NDT Level III Examination - Ultrasonic Testing

Preparatory Notes for ASNT NDT Level III Examination - Ultrasonic Testing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

As implemented in contemporary digital flaw detectors, DGS curves are<br />

typically plotted based on a reference calibration off a known target such as a<br />

backwall reflector or a flat bottom hole at a given depth. From that one<br />

calibration point, an entire curve set can be drawn based on probe and<br />

material characteristics. Rather than plotting the entire curve set, instruments<br />

will typically display one curve based on a selected reflector size (registration<br />

level) that can be adjusted by the user. In the example below, the upper curve<br />

represents the DGS plot <strong>for</strong> a 2 mm disk reflector at depths from 10 mm to 50<br />

mm. The lower curve is a reference that has been plotted 6 dB lower.<br />

In the screen at left, the red gate marks the reflection from a 2 mm diameter<br />

flat bottom hole at approximately 20 mm depth. Since this reflector equals the<br />

selected registration level, the peak matches the curve at that depth. In the<br />

screen at right, a different reflector at a depth of approximately 26 mm has<br />

been gated. Based on its height and depth in relation to the curve the<br />

instrument calculated an ERS of 1.5 mm.