Q5: <strong>Ultrasonic</strong> inspection is being <strong>for</strong> a circumferential weld of a pressure<br />

vessel. Equipment is calibrated at the beginning of the examination and<br />

scanning started at 9.00 AM. In between calibration is also done and at<br />

12.00 noon the equipment is not functioning properly. Still 30 % of weld<br />

is to be examined. As per procedure and as level II one can:<br />

A. go ahead with the scanning by doing recalibration<br />

B. per<strong>for</strong>m the inspection fully from the beginning after recalibration<br />

C. bring another equipment and proceed scanning from the left out place<br />

D. check and recalibrate the equipment and continue scanning<br />

from the portion where scanning started after calibration<br />

at 11.00 AM