Q3-23 A air filled #3 FBH 0.5” into the bottom of 4.5” aluminum block, will<br />

return to the 0.75” diameter sending immersion transducer ans echo signal<br />

equal to ? Of the initial pulse. Assume no attenuation to beam divergence or<br />

other causes.<br />

Answer:<br />

The size of reflector = 3/64” = 0.046875”.<br />

For a small reflector used inverse square law;<br />

Echo1/Echo2 = Area 2 / Area 1<br />

100/x= 0.046875 2 / 0.75 2 , x = 0.39%