09.09.2014 Views

Preparatory Notes for ASNT NDT Level III Examination - Ultrasonic Testing, UT

Preparatory Notes for ASNT NDT Level III Examination - Ultrasonic Testing

Preparatory Notes for ASNT NDT Level III Examination - Ultrasonic Testing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

In challenging applications requiring low frequency transducers <strong>for</strong> increased<br />

penetration, the Videoscan Replaceable Face Transducers and appropriate<br />

high temperature delay lines can also be used with 38DL PLUS and 45MG<br />

thickness gages incorporating the HP (high penetration) software option.<br />

Custom transducer setups will be required. Standard delay lines <strong>for</strong> this<br />

family of transducers can be used in contact with surfaces as hot as 480° C<br />

or 900° F. For a full list of transducers and delay lines, see this link:<br />

Replaceable Face Transducers.