Q12: The 1 MHz transducer that should normally have the best time of<br />

distance resolution is a:<br />

A. Quartz crystal with air backing<br />

B. Quartz crystal with phenolic backing<br />

C. Barium titanate transducer with phenolic backing<br />

D. Lithium Sulphate transducer with epoxy backing<br />

Hint: 1 MHz as Lithium Sulphate is not easily cut to very thin thickness, best<br />

distance resolution due to the fact the Lithium Sulphate is the best receiver of<br />

ultrasound energy.