Arrows shown standard correct answers:<br />

3-Screen Height Linearity<br />

The ultrasonic testing instrument shall provide linear vertical presentation<br />

within ±5% (According to ASME Sec.V, Article 5 T-532) of the full screen<br />

height <strong>for</strong> 20% to 80% of the calibrated screen height.<br />

The procedure <strong>for</strong> evaluating screen height linearity is provided in appendix 1<br />

of article 5, ASME code Sec.V and shall be per<strong>for</strong>med at the beginning of<br />

each period of extended use (or every 3 months, which ever is less).<br />

http://www.inspection-<strong>for</strong>-industry.com/ultrasonic-testing.html