AS-3640
AS-3640
AS-3640
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Pos: 86 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Troubleshooting (all printers)/8.2a_Ü3_Band läuft nicht mehr an_<strong>AS</strong>-OrbitBase/CSV-810 @ 0\mod_1254147013765_912.doc @ 3891 @ 3<br />
Pos: 87 /Bedienungsanleitungen/Geräte spezifisch/Drucker/<strong>AS</strong>-OrbitBase/8.2b_Überschrift Fuse exchange <strong>AS</strong>-OrbitBase control unit @ 2\mod_1267188940605_912.doc @ 12592 @<br />
Pos: 88 /Bedienungsanleitungen/Geräte spezifisch/8.2b_Sicherungswechsel_250V 3.15A T_EG2008.050_mit Schalter @ 2\mod_1267189327835_912.doc @ 12605 @<br />
Pos: 89 /Bedienungsanleitungen/Geräte spezifisch/Drucker/<strong>AS</strong>-OrbitBase/8.2b_Überschrift Fuse exchange <strong>AS</strong>-OrbitBase conveyor @ 2\mod_1267189061755_912.doc @ 12596 @<br />
8.2 Troubleshooting<br />
8.2.1 The conveyor transport doesn’t work<br />
Condition Problem Solution<br />
The transport doesn’t work.<br />
The power is cut, or the<br />
release button is not<br />
activated.<br />
Check whether the green<br />
release button is flashing or<br />
off. Press the button to<br />
release the emergency stop<br />
function.<br />
Check the correct connection<br />
of the power cable.<br />
Check the fuses of the<br />
device.<br />
Fuse exchange for the <strong>AS</strong>-<strong>3640</strong> control unit:<br />
Fuse exchange<br />
Attention!<br />
Disconnect the device from the power outlet before exchanging the<br />
fuses.<br />
Data<br />
Type<br />
Dimensions<br />
Voltage<br />
Glass tube microfuse<br />
5 x 20 mm<br />
250 V<br />
Amount 2<br />
3.15 A (T)<br />
Figure 1: Exchange of the fuses<br />
Use a flat screwdriver to swing open the fuse holder cover. Take the<br />
holder out of the power input module. Both fuses need to be intact.<br />
Change the blown fuses and insert the holder again.<br />
User Manual Version 3.1 127