Pos: 75.77 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü3_1804_RELAY2 OUTPUT_<strong>AS</strong>-3060A, 620, Orbit, OrbitB @ 0\mod_1254913755613_912.doc @ 4855 @<br />

on print base<br />

SET TIME[s]<br />

on serial belt<br />

SET TIME[s]<br />

on 3rd party belt<br />

SET TIME[s]<br />

downstream from the printer.<br />

on print base<br />

Use this setting when the dryer is mounted on the<br />

same Neopost Base conveyor as the print unit(s). The<br />

dryer will be turned off when a stop of this conveyor is<br />

detected by the printer. At SET TIME[s] you can set<br />

the duration (in seconds) the dryer remains turned on<br />

after the last pages exited the printer.<br />

(0 – 60 sec. / Default: 5 seconds)<br />

on serial belt<br />

Use this setting when the dryer is mounted on a serial<br />

connected Neopost conveyor. The dryer will be turned<br />

off when a stop of this conveyor is detected by the<br />

printer. At SET TIME[s] you can set the duration (in<br />

seconds) the dryer remains turned on after the last<br />

pages exited the printer.<br />

(0 – 60 sec. / Default: 5 seconds)<br />

on 3rd party belt<br />

Use this setting when the dryer is mounted on a third<br />

party conveyor belt which is controlled independently<br />

from the printer. At SET TIME[s] you can set the<br />

duration (in seconds) the dryer remains turned on<br />

after the last pages exited the printer.<br />

(0 – 60 sec. / Default: 5 seconds)<br />

divert<br />

DISTANCE<br />

Using a dryer!<br />

Review all settings carefully before using a dryer!<br />

Never operate a dryer without supervision of an operator!<br />

Control option for a diverter placed behind the printer<br />

(inline). The distance between paper sensor and<br />

device has to be entered (range 0 – 5,000 mm). The<br />

width (duration) of the signal pulse is calculated from<br />

the transport speed and the material size in transport<br />

direction. Any device in-between the printer and the<br />

diverter can influence the distance.<br />

divert works for devices which are downstream from<br />

the printer.<br />

Trigger divert<br />

The divert function must be<br />

triggered from a PC application.<br />

Default: feeder control<br />