Bar Graphs, Meters, <strong>and</strong> Trends 163The HMI reads from the Sampling Object datalog file (*.dtl) immediately after the screen that contains the HistoryData Display object is displayed. The data is only read <strong>and</strong> updated whenever the screen is first displayed. Data recorded to the datalog file (*.dtl)after the History Data Display object is shown will not appear on the History Data Display object until the screen isrefreshed (closed, then opened again). A maximum of 20 channels can be displayed.To create a History Data Display Object:1. From the Objects menu, click History Data Display, or click the History Data Display icon in the Object 2toolbar. The New History Data Display dialog box appears:0600-0069-0000 <strong>Rev</strong>. B