182 <strong>Silver</strong> <strong>Series</strong> Programming <strong>Manual</strong>A developer can set the HMI key in the reserved local memory of the HMI (LW9046 configured for 32-bit unsignednumeric format). This value is stored in non-volatile memory, <strong>and</strong> once it is set, the value is hidden <strong>and</strong> cannot beread using a numeric display. In this way, only HMIs with the correct HMI key will be able to run the project. If theProject key does not match the HMI key, local bit LB9046 is set <strong>and</strong> the driver is disabled <strong>and</strong> will not communicatewith the PLC. The HMI must be rebooted in order for the HMI key setting to take effect.This feature is not available on the X-models (HMI5104XH, HMI5121X, HMI5150X).Disable Upload FunctionActivate the Disable Upload Function in the System Parameter settings (Edit > System Parameters > System Settingtab). Alternately, you can set LB9033 in the local reserved memory of the HMI to disable the upload function <strong>and</strong>prevent a project from being uploaded from the HMI. The HMI must be rebooted after downloading the project in order for the Disable Upload Function to take effect.0600-0069-0000 <strong>Rev</strong>. B