10.07.2015 Views

Silver Series Installation and Operation Manual, Rev B ... - Watlow

Silver Series Installation and Operation Manual, Rev B ... - Watlow

Silver Series Installation and Operation Manual, Rev B ... - Watlow

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

64 <strong>Silver</strong> <strong>Series</strong> Programming <strong>Manual</strong>The Message tab allows you to enter a message that will appear in the Alarm Bar, Alarm Display, or Event Displaywhen the alarm/event is triggered. The Write value for Event Display object is used to enter a window number that iswritten to the Write address configured in the Event Display object. This window number is used by an IndirectWindow configured to popup when an alarm/event is acknowledged.For HMI5000 models with the audio line-out option, a sound can be played when the alarm/event is triggered. Clickthe Enable button <strong>and</strong> select a sound from the Sound Library.The WATCH addresses can be used to display the data in up to four registers in messages. Click the Syntax button tosee how to configure the message to display the data.Data Transfer (Trigger-based)The Data Transfer (Trigger-based) Object is used to transfer word-based data from the specified Source address(es) tothe specified Destination address(es). This can be used to transfer data from one device to another.The Source <strong>and</strong> Destination address fields define the starting addresses, <strong>and</strong> the No. of words field specifies howmany consecutive addresses are transferred. The data transfer can be triggered by touch (Touch trigger mode) or byan external or internal bit (External trigger mode).BackupThe Backup Object is used to copy recipe files (*.rcp), event files (*.evt), <strong>and</strong> data files (*.dtl) from the HMIs internalmemory to a USB flash drive or a PC connected via Ethernet.When Historical event log or Historical data log is selected, the historical event logs or data logs can be saved in theirnative file formats (*.evt or *.dtl respectively) or in *.csv format. The range of history files can be selected <strong>and</strong> thebackup can be triggered by touch (Touch trigger mode) or by an external or internal bit (External trigger mode).When the backup process starts, local bit LB9039 is set. When the backup is complete, local bit LB9039 is reset.Note: The Backup object does not copy PLC register data.TimerThe Timer Object is used to control an output bit based on the state of an input bit <strong>and</strong> a measurement bit that iscontrolled by a preset time. There are five different configurations or modes for the timer including On Delay, OffDelay, Pulse, Accumulated On Delay, <strong>and</strong> Accumulated Off Delay.When placed on a window, a timer object is invisible so there are no shape or label properties to configure.PLC ControlThe PLC Control Object is used to perform a number of background tasks. Click the New button to set up a controlobject. Click Type of control to open a drop-down box with the following options:Change WindowThis causes the HMI to close the currently-displayed Base Window, <strong>and</strong> display the Base Window whose number is inthe specified Trigger address.The Change Window action occurs only when the HMI detects a change in the value of the specified Trigger Address.After the window is changed, the HMI will write the number of the newly-displayed window to (Trigger Address +1).0600-0069-0000 <strong>Rev</strong>. B

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!