hager TX216 KNX/EIB DALI-Gateway - UTU
hager TX216 KNX/EIB DALI-Gateway - UTU
hager TX216 KNX/EIB DALI-Gateway - UTU
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>hager</strong>"<strong>DALI</strong> <strong>Gateway</strong> C00Cx2" softwareParameters4.2.5 ParametersDescription: Values: Remarks:General<strong>DALI</strong> error statusfeedback ?Yes, feedback object is activemessage objectYes, feedback object ispassive status objectNoThe error status of the <strong>DALI</strong> devices can bereported to the bus. Setting "Yes" activatesthe reporting function and enables thecorresponding object.Moreover, the parameter defines whetherthe feedback telegrams are transmittedactively (telegram transmission in case ofchanges) or passively (telegramtransmission only as a response to a Readrequest). The communication flags of theobject are automatically set by the ETSaccording to the setting.<strong>DALI</strong> <strong>Gateway</strong> mainsvoltage failure/returnfeedback ?Yes (in case of voltage failureand return)Yes (only in case of voltagefailure)NoThe <strong>DALI</strong> <strong>Gateway</strong> is able to monitor itssupply voltage (mains voltage connection)and can transmit a message telegram tothe bus in case of failure even beforeshutting down.Setting "yes" activates the reportingfunction and enables the correspondingobject.Moreover, it determines whether themessage is to be transmitted only in caseof supply voltage failure or also in case ofsupply voltage return.<strong>DALI</strong> short-circuitfeedback ?YesNoThe <strong>DALI</strong> <strong>Gateway</strong> can transmit amessage telegram to the bus if it detects ashort-circuit in the <strong>DALI</strong> line.The "yes" setting activates the reportingfunction and enables the correspondingobject.Alternatively, the “no” setting deactivatesthe short-circuit message.• The “<strong>DALI</strong> short-circuit” or “<strong>DALI</strong> voltagefailure” messages will only be triggered ifthe corresponding event has taking placeand in case the mains voltage for the<strong>DALI</strong> <strong>Gateway</strong> is active.• The “<strong>DALI</strong> error status”, “<strong>DALI</strong> shortcircuit”or “<strong>DALI</strong> voltage failure”messages will not automatically betransmitted to the bus after the return ofbus voltage with bus voltage applied atthe <strong>DALI</strong> <strong>Gateway</strong>.Seite 104 von 130