<strong>hager</strong>"<strong>DALI</strong> <strong>Gateway</strong> C00Cx2" softwareFunctional descriptionFeedback for <strong>DALI</strong> short-circuitThe <strong>DALI</strong> <strong>Gateway</strong> detects short-circuits in the <strong>DALI</strong> line – for instance in case of an installation error.As soon as a short-circuit has been identified in the <strong>DALI</strong> line (with mains voltage applied), the <strong>DALI</strong><strong>Gateway</strong> will send a feedback to the <strong>KNX</strong>/<strong>EIB</strong> if the feedback function has been enabled for a <strong>DALI</strong>short-circuit.The <strong>DALI</strong> <strong>Gateway</strong> utilizes the independent “<strong>DALI</strong> short-circuit” 1-bit communication object 212 for a<strong>DALI</strong> short-circuit feedback. The polarity of the telegram is preset: (no short-circuit = 0, short-circuit = 1)Setting the feedback for <strong>DALI</strong> short-circuitThe ETS allows to set parameters that determine whether a <strong>DALI</strong> feedback on a short-circuit is to betransmitted to the <strong>KNX</strong>/<strong>EIB</strong>. If enabled, the telegram is always actively transmitted. If a short-circuit hasbeen detected or eliminated, the <strong>Gateway</strong> will transmit a feedback telegram in each case.• Set the "<strong>DALI</strong> short-circuit feedback ?” parameter on the "General" parameter page to "Yes".The <strong>DALI</strong> short-circuit feedback is activated and the communication object is enabled.• Set the "<strong>DALI</strong> short-circuit feedback ?” parameter on the "General" parameter page to "No".The <strong>DALI</strong> short-circuit feedback function is deactivated. The communication object is hidden.• The connected <strong>DALI</strong> devices will also respond to a short-circuit in the <strong>DALI</strong> line. The devices willadjust to the preset "SystemFailureLevel". This value will be programmed into the <strong>DALI</strong> devicesduring the commissioning of the <strong>DALI</strong> <strong>Gateway</strong> and corresponds to the “Response to bus voltagefailure” value that can be parameterized in the ETS for each group.• Because the brightness of the connected <strong>DALI</strong> devices might possibly change in case of a shortcircuit("SystemFailureLevel"), the <strong>DALI</strong> <strong>Gateway</strong> will also transmit feedback on the switching stateand brightness value to the bus if these feedback functions have been enabled.• Feedback on a <strong>DALI</strong> short-circuit can only be transmitted if the bus voltage has been connected andswitched on at the time of the short-circuit.In case no bus voltage has been connected or switched on at the time of the short-circuit, there willalso be no feedback transmission. The feedback, however, will be stored so it can be transmitted ata later time after the bus voltage has been applied.• The <strong>DALI</strong> <strong>Gateway</strong> initializes after the ETS programming or after the mains voltage has beenapplied. If a short-circuit has been detected in the <strong>DALI</strong> line, the <strong>Gateway</strong> will proceed to transmit thecorresponding feedback telegram. The “<strong>DALI</strong> short-circuit” will not be automatically transmitted to thebus after the return of bus voltage (mains voltage at the <strong>Gateway</strong> is permanently switched on duringbus failure).Seite 39 von 130

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!