10.07.2015 Views

hager TX216 KNX/EIB DALI-Gateway - UTU

hager TX216 KNX/EIB DALI-Gateway - UTU

hager TX216 KNX/EIB DALI-Gateway - UTU

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>hager</strong>"<strong>DALI</strong> <strong>Gateway</strong> C00Cx2" softwareFunctional description• If applicable, select another group from the right subwindow.All available devices will again become visible in the left subwindow if no assignment has yet beenmade for the selected group.• Again, assign one or several available <strong>DALI</strong> devices to the group.The assigned devices will be removed from the list box in the left subwindow and will appear for theselected group in the right window.• If applicable, proceed with group assignments as described.• Several devices can be assigned to the groups 1...16. Only one device can be assigned to each ofthe groups 17...32.• It is possible to have devices assigned to more than just one group. In case a device alreadyassigned is to be assigned another group, the plug-in will report that the device has already beenassigned to a different group and that switching status and brightness value feedbacks can no longerbe unique. Once the message has been confirmed, the plug-in will proceed to create the overlappingassignment. Devices that have been assigned several groups will be identified by a “*” in the rightsubwindow.• <strong>DALI</strong> devices that are assigned several groups will always adjust to the state adjusted last via one ofthe assigned groups. In this case, the switching status or the brightness value feedback of a group isnot necessarily unique.Example 1: Group 2 is set to 10% brightness. Group 3 is then dimmed to a brightness value of 20%.The lamps of group 3 will accept the brightness value of 20% that was called up last. The feedbackof group 2 remains on 10%, although some of the devices that belong to the group have been set to20% brightness.Example 2: group 2 is switched on and assumes the brightness value of 100%. The status of group 3remains at 0% brightness (OFF) internally in the <strong>DALI</strong> <strong>Gateway</strong>. The brightness of group 3 has nowbeen increased. The lamps of group 3 will adjust to the dimming (increasing brightness starting atminimum brightness) even though these lamps had been switched on before via group 2.Basically, the assignment of <strong>DALI</strong> devices to groups is arbitrary. For the reasons mentioned above itis recommended not to assign the devices to several groups at the <strong>DALI</strong>. Preferably, the devicesshould be allocated to separate instead of overlapping groups. A <strong>KNX</strong>/<strong>EIB</strong> link via the groupaddressing in the ETS is also preferred.• In the plug-in each group can be separately parameterized. During the programming with the ETS,the individual <strong>DALI</strong> devices will be programmed with the parameter data of the assigned groups. Alldevices assigned to a <strong>DALI</strong> group will be put into operation in the exact same way.If, however, <strong>DALI</strong> devices have been assigned to several groups these devices will receive theproject design with the highest group number.• By activating the “Delete assignment” button in the lower margin of the commissioning environmentall assignments between the <strong>DALI</strong> devices and the different groups can be deleted. However, notonly the assignments will be reset in the plug-in but the commissioning parameters of the <strong>DALI</strong><strong>Gateway</strong> will also be adjusted. The plug-in will establish a communication to the <strong>Gateway</strong> via the busconnection of the ETS 3 and delete all assignment in the device memory. This may take some time.The progress is shown during the deleting. In case of a faulty bus communication the plug-in willabort the operation without deleting any assignments in the project design or in the device.<strong>DALI</strong> devices previously identified are not deleted but will have no group assignments.Seite 93 von 130

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!